Timing calibration of the GRM onboard SVOM
SVOM 卫星 GRM 探测器的在轨时间标定
We present an in-orbit timing calibration of the Gamma-Ray Monitor (GRM) onboard the Space-based Multi-band Variable Object Monitor (SVOM), based on Crab pulsar observations from 2024 July to 2025 March. The three GRM detector units are processed independently with a common timing-analysis pipeline. To improve long-baseline phase coherence, we combine a global high-signal-to-noise Crab template with monthly ephemerides derived from the GRM data themselves. The three units yield consistent post-fit residuals, with most values within ± 60 μs and an RMS of about 18 μs. This RMS includes contributions from observing conditions, counting statistics, template construction, ephemeris uncertainty, and the processing chain. This RMS should therefore be interpreted as an observational upper bound on the combined timing uncertainty rather than as a direct measurement of intrinsic detector jitter. Applying the same ephemerides to contemporaneous Fermi/LAT Crab data yields post-fit residuals with an RMS of about 27 μs. These residuals follow the SVOM/GRM trend within the statistical uncertainties and show no monotonic long-term drift, with the dominant inter-instrument difference absorbed by a constant timing offset, supporting the cross-mission transferability of the GRM timing solution. Energy-resolved pulse profiles from 10--30 keV to above 100 keV recover the expected strengthening of the interpulse and bridge emission with increasing energy. These results demonstrate stable sub-20 μs post-fit relative timing residuals for the current data set, supporting precision pulsar timing, transient temporal analysis, and multi-mission high-energy studies.
展开 ▾采用自洽月历表和高信噪比模板,三个探测器单元独立处理获得一致的 ±60 μs 以内、RMS 约 18 μs 的残差;该方法跨任务可转移,为多信使高能研究提供精准计时基础。
利用蟹状星云脉冲星对高能探测器进行在轨时间标定是检验绝对时间精度的重要手段,此前已被广泛应用于多个任务。本研究针对 SVOM/GRM 的特性,发展了结合全局模板与月历表的长基线相位相干化方法,将相对计时残差控制在 20 μs 以下,并证实与 Fermi/LAT 无显著系统漂移。该方法未来可推广至 SVOM 其他载荷及多信使联合观测中,实现跨任务亚十微秒级的高精度时间联合分析。
刊出 2026-09-05 · 收录 2026-09-23